Abstract

Autogenous vein graft was used to fill 18 digital nerve defects between 0.5 to 5.8 cm in length during flexor tendon surgery in zone 2. The vein was taken from the forearm and reversed to bridge the digital nerve. For nerves with defects over 2.0 cm, normal nerve slices were inserted inside vein conduits. Recovery of sensibility was evaluated by von Frey test, pin-prick detection, localization of stimulus, moving two-point discrimination and sweating on the finger pulp. Follow-up revealed excellent recovery in two digital nerves, good in nine, fair in five and poor in two. The results suggest that vein graft provides a simple and practical method to reconstruct a digital nerve defect during tendon repair in zone 2.