Abstract

Minimally invasive mitral valve surgery (MIMVS) has become the standard approach for mitral valve pathology in many centres. The anterolateral mini thoracotomy access is beneficial in reoperative surgery by avoiding repeat sternotomy associated risks. The aim of this study is to analyse the safety of this technique. All patients undergoing reoperative MIMVS between 2008 and 2019 were studied retrospectively. Primary endpoint was 30-day major complications and mortality; secondary outcome was long term survival, reoperation rate and rate of more than moderate recurrent regurgitation. 146 Patients underwent reoperative MIMVS with a mean age of 68 ± 8 years. The composite outcome of 30-day major complication and mortality was 29.5%. 30-Day mortality was 6.2% and stroke rate 3.4%. Survival for the whole cohort was 89.7 ± 2.5% at 1-year, 71.6 ± 4.3% at 5 year and 50.9 ± 5.9% at 8-year follow up. Cox regression analysis revealed reduced left ventricular function (HR 2.8; 95%CI 1.5 - 5.0), GFR < 60 (HR 2.1; 95%CI 1.2 - 3.7) and active endocarditis (HR 6.4; 95%CI 2.7 - 15.4) as variables associated with reduced long-term survival. The cumulative incidence of re-operation after mitral valve replacement was 11.3 ± 3.2% at 5-year and for repair 16.2 ± 7.5% at 5-year. The cumulative incidence of more than moderate recurrent regurgitation after mitral valve repair was 25.4 ± 9.0% at 3-year. Minimally invasive access in reoperative mitral valve surgery in the current study showed similar 30-day mortality and stroke rate compared to repeat sternotomy results reported in literature.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call