Abstract
Accurate measurement of pressure gradients on echocardiography across a Starr-Edwards (SE) ball valve is difficult due to its unique flow pattern. The decision of indication for reoperation on the valve requires multifactorical evaluation. We report a surgical case with an aortic SE ball valve 43 years after implantation. There was no apparent structural deterioration on the ball per se, yet, remarkable pannus formation was noted beneath the sewing cuff in the left ventricular outflow tract.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.