Abstract

• In a prospective, controlled study undertaken to assess renal function following infusion of radiologic contrast material, serum creatinine level was determined before scan and for three days after scan in 193 patients undergoing computed tomographic (CT) brain scan with contrast enhancement (contrast medium volume, 60 to 350 mL) and in 233 controls undergoing CT scan without infusion. Renal failure developed in four patients who had infusion of contrast material and in three patients who had no infusion (≥50% increase in serum creatinine level and above normal). In the high-risk group (serum creatinine level ≥1.5 mg/dL or diabetes mellitus), renal failure developed in none of the 19 patients infused and in two of 46 in the noninfused group. It was concluded that previous uncontrolled studies may have overestimated the risk of renal failure induced by contrast material. ( Arch Intern Med 1985;145:87-89)

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call