Abstract
Electrolytic manganese residues containing a substantial amount of manganese are a potential pollution. Removing water-soluble manganese ions from electrolytic manganese residues by hydrometallurgical process was discussed. In the work, the basic property of the electrolytic manganese residues was analyzed. Based on it, we proposed the suitable method to remove Mn2+ from the slag by pollution-free oxidation in alkaline solution. The results shown that the best conditions to remove Mn2+ were pH 10.5, temperature 55 °C, the flow rate of hydrogen peroxide 0.50 mL·L-1·min-1 and agitation speed 250 r/min. At the optimum condition, the removal ratio of water-soluble Mn2+ exceeded 99.9% and the concentration of Mn2+ in the final solutions was about 3 mg/L.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.