Abstract

Viral safety is an important prerequisite for clinical immunoglobulin preparations. A common manufacturing practice is to utilize several virus removal/inactivation process steps to ensure the safety of human intravenous immunoglobulin (IVIG). In this regard, we examined the use of Planova 35 nm filters to reduce potential loads of both non-enveloped and enveloped viruses prior to end-stage solvent detergent treatment. The nanofiltration process was validated for removal of a variety of enveloped and non-enveloped viruses ranging in size from 70 nm to 18 nm including: Sindbis virus, Simian Virus 40 (SV40), Bovine Viral Diarrhoea virus (BVDV), Feline Calicvirus, Encephalomyocarditis virus (EMC), Hepatitis A virus (HAV), Bovine Parvovirus (BPV) and Porcine Parvovirus (PPV). The filtration procedure was carried out by first spiking a 7% solution of IVIG with <108virus. The spiked IVIG solution was then filtered through a 75 nm Planova filter followed by two Planova 35 nm filters in series (75/35/35). The 75 nm prefilter is incorporated into this process to increase the capacity of the 35 nm viral removal filters. As a result of the inclusion of the 75 nm pre-filtration step it was possible to assess the removal of virus by the 35 nm filters independent of possible aggregation of the initial viral spiking material. Samples were collected at each step and immediately titred by viral plaque assay. A process control sample of the spiked load solution was held at the same conditions for the duration of the filtration process and then titred to determine the extent to which antibody neutralization may have contributed to overall viral reduction. Control assays of spiked IVIG were performed to establish the degree of toxicity of the IVIG solution to the indicator cell lines and the extent to which the IVIG interfered with plaque formation in the assay system. This combined data was used to establish assay sensitivity for the calculation of log removal by the filtration process. It was noted that toxicity/interference effects could have a significant effect upon apparent log reductions, and these effects could vary greatly, even within viruses of the same family. The results of these studies indicate that 35 nm filtration is very effective for removing substantial quantities of both non-enveloped and enveloped viruses from IVIG. Complete clearance (to the limits of detection of the assay) was obtained for all viruses larger than 35 nm. Interestingly, viruses reported to have mean diameters of less than 35 nm (EMC and HAV) were at least partially removed by the filtration (4·3 and >4·7 logs removal, respectively). Even small viruses such as PPV were to some extent removed from the IVIG solution by the filters (2·6 logs removal). Reduction of BPV would not be assessed due to extensive neutralization and interference with plaque formation by the IVIG. Sindbis and SV40 also were subject to neutralization and assay interference due to the IVIG, though to a lesser extent. We conclude from these studies that the 35 nm mean pore size is functionally efficient in removal of smaller size viruses from spiked IVIG concentrates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.