Abstract

Therapeutic and prophylactic vena cava filters (VCFs) are used to prevent pulmonary embolism. Concerns exist over placing a permanent filter in a young trauma patient. Recently, retrievable VCFs have become available. One such filter is the OptEase, which has a recommended time of removal of up to 23 days after insertion. Data supporting this recommendation are sparse. Many trauma patients will need filters for more than 2 weeks, and there are no data evaluating the safety of removal after extended time periods. The purpose of this study was to determine the safety, feasibility, and reaction of the vena cava when removing the OptEase retrievable VCF at different time intervals. Twenty Yorkshire cross pigs (80-113 kg) underwent general anesthesia with tiletamine and zolazepam. Filters were placed in the infrarenal vena cava (VC) through the femoral vein under fluoroscopic guidance. Animals were then divided into four groups. In group 1, filters were removed at 14 days; in group 2, at 30 days; in group 3, at 60 days; and in group 4, at 90 days. Removal was attempted using a snare-and-sheath technique through the femoral vein. Animals with successful filter removal were allowed to recover; then, the animals underwent autopsy (gross and microscopic VC examination) 2 months later. Animals with unsuccessful filter removal underwent autopsy immediately after attempted removal. Venacavograms were taken at filter insertion, at removal, and before autopsy to evaluate any VC abnormalities. Successful removal of the filter in all five pigs (100%) was reliably performed only in the 14-day group. In this group, the initial VC transverse diameter was 19.4 +/- 0.8 mm and was significantly reduced to 9.8 +/- 1.1 mm (p < 0.05) immediately after removal. Sixty days later, before autopsy, VC diameter had increased to 15.3 +/- 1.9 mm, which was significantly larger than at removal (p < 0.05) but not different from the initial value. In the 30-day group, removal was successful in only one of five animals. Although removal was successful in the one pig, autopsy at 2 months postremoval revealed total occlusion of the VC. Filters could not be removed from 60- and 90-day groups. At autopsy, the VCF struts were embedded or protruded through the VC wall. Microscopic examination of the VC revealed significant scarring underneath and between the struts. Removal of the retrievable OptEase VCF may be successfully performed up to 14 days after insertion. Strut protrusion through the VC wall prohibited successful and safe removal at extended time intervals.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.