Abstract
The removal of scale by high gradient magnetic separation (HGMS) has been investigated utilizing the magnetic properties of the scale. This study focuses on a thermal power plant with oxygen treatment (OT), which has been applied in many new power plants with large generation capacity in recent years. At high-temperature conditions where the HGMS system is expected to be installed, the viscosity of the fluid will be lower than that of at room temperature, which makes the separation ratio higher. In this study, the scale capture rate at room temperature (25°C) and 80°C was investigated by particle trajectory calculation and experiment, in order to design magnetic separation conditions suitable for the high-temperature environment of the chemical cleaning line of the thermal power plant adopting OT.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.