Abstract

Eye activity has larger electrical potential than the average electroencephalogram (EEG) recording, thus making it one of the major sources of artefacts. Ocular artefacts (OA) must be removed as completely as possible with little or no loss of EEG to obtain a higher quality EEG. Using independent component analysis (ICA), the EEG is separated into independent components (IC) and the contaminated component is removed, thus removing the OA. However, ICA does not separate the sources completely and some of the meaningful EEG is lost. In this paper, a new method combining ICA and wavelet neural networking (WNN) is proposed. In this method, WNN is applied to the contaminated ICs, correcting the OA and thus lowering the data lost. The method was evaluated using simulated and real datasets and the results show that the OA are successfully removed with very little data loss.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.