Abstract

Grey water is a kind of domestic wastewater including shower, bath, lavatory and laundry waters. Grey waters without faecal waste can be considered as alternative water sources in the place where water resources are limited. In the present study, the removals of COD, anionic and non-ionic surfactants from grey water via conventional (CFP) and modified (MFP) Fenton oxidation processes was experienced. It was determined that pH adjustment to acidic values is not required in CFP. The optimum operating conditions were determined as [Fe2+] = 50 mg/L, [H2O2] = 50 mg/L at pH 7.6 (original pH) in CFP and [ZVI] = 50 mg/L, [H2O2] = 50 mg/L at pH 3 in MFP, respectively. As a result, the CFP has been found to be a more efficient alternative treatment method for the treatment of grey water, compared to MFP.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.