Abstract

The study of blood-tissue exchange by the multiple indicator dilution technique often needs frequent sampling in the blood of the indicator dilution curves (IDC). Usually, this requires the use of a catheter supported by a pump. This causes a distortion in the IDC, which must be removed for proper interpretation of the data. A deconvolution-based methodology to remove IDC distortion is presented. First, the catheter impulse response is modelled by means of data obtained from a suitable experiment. Then the reconstruction of the blood IDC is tackled by a new nonparametric deconvolution algorithm, which provides (quasi) time-continuous signals and exploits statistically based criteria for the choice of the regularisation parameter. The methodology is applied to the removal of catheter distortion in studies of glucose blood-tissue exchange in the human forearm and myocardium.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.