Abstract

In this work, removal of arsenic from contaminated water was carried out using coagulation followed by polyelectrolyte enhanced ultrafiltration (PEUF). Ferric chloride and polydiallyldimethylammonium chloride (polyDADMAC) were used as coagulant and cationic polyelectrolyte, respectively. In the first step, effect of coagulant concentration on removal of arsenic was studied and coagulant dosage was optimized. In the second set of study, a combination of low dose of coagulant and polyelectrolyte solution was used for treatment of arsenic contaminated water. The supernatant collected following coagulation was subjected to PEUF so as to remove the residual arsenate ions. Ultrafiltration (UF) was carried out in a tangential flow module fitted with 5 kD polyethersulfone (PES) membrane. During UF, influence of polyelectrolyte dosage and transmembrane pressure (TMP) on permeate flux and arsenic rejection were investigated and optimum values were reported. It was observed that small dose [1 mL PE (polyelectrolyte)/50 mL of sample] could effectively reduce the residual arsenic concentration below permissible maximum contaminant level of 10 ppb. A 99.2% rejection of arsenic was recorded during ultrafiltration at a TMP of 2.5 bar following treatment with 0.234 mM polyelectrolyte solution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.