Abstract

Conventional scrubbers are typically modified to serve the needs of modern industries that discharge effluents that cause synergetic, adverse effects on the environment. We designed and developed a modified turbulent wet scrubber (MTWS) to remove air pollutants as they emerge from a coal furnace. Experiments were conducted to estimate the pressure drop and the efficiencies of ammonia gas and particulate removal via the MTWS. The optimum water levels and gas flow rates for effective scrubbing of ammonia gas at different concentrations and particulate matter at different feed rates were estimated. For ammonia gas at a concentration of 45ppm, a gas flow rate of 3.5m3/s and a water level of 58cm in MTWS and position B (central position of the nozzle) in the water level of the nozzle yielded efficient ammonia gas removal for the given time. Similarly, for a fly ash feeding rate of 140mg/min, the same gas flow rate and water level in the MTWS yielded high efficiencies even for particles at the submicron level.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.