Abstract

Optical clocks can be used as the absolute frequency reference due to their high accuracy and stability. In a precise optical clock transmission system, the instability loss of the link is usually evaluated by beating the remote optical signal with the reference clock, which is not suitable for real frequency distribution applications. Therefore, it is necessary to assess the performance directly at the remote site for the optical frequency transfer, because the two sites of the link are usually not co-located. In this paper, we proposed a comb-based remote residual instability evaluation scheme. Two coherent optical combs with different wavelengths were extracted from a frequency stable comb and transmitted after multiplexing. The residual instability was evaluated directly at the remote site by measuring the phase fluctuation difference between the two combs. We achieved 8.61 × 10−19 at 40,000 s over a 10 km fiber link, reaching the instability of optical clocks. These results revealed that our scheme can evaluate optical clock frequency transmission directly at the remote site, which made the method truly practical.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.