Abstract

Funding AcknowledgementsType of funding sources: None.BackgroundRemote monitoring (RM) for implantable cardioverter defibrillators (ICDs) is recommended as the standard of care in clinical guidelines. Presumably, the restrictions on face-to-face visits that were imposed during the coronavirus (COVID-19) pandemic have further accelerated the adoption of RM. However, quantitative real-world data on the uptake of RM during the COVID-19 pandemic is lacking.PurposeTo assess the uptake of RM during the COVID-19 pandemic to a pre-COVID-19 period, and compare the arrhythmic burden between the two groups.MethodsThis is a substudy of the retrospective, observational single-center DISTANT-study. For this substudy, data from patients who were enrolled in the RM program after de novo ICD implantation (single- and dual chamber, biventricular or subcutaneous ICDs) were analysed. The time until RM was initiated per patient was calculated for patient implanted during the COVID-19 pandemic (March 2020-January 2021) and compared to a similar 10-month period pre-COVID-19 (May 2019-March 2020). ICD therapy (shock and/or anti-tachycardia pacing), non-sustained ventricular tachycardia (NSVT), supraventricular tachycardia (SVT) and mortality were registered for each patient. Patients <18 years old at implantation and patients with a follow-up of <6 months were excluded from this analysis.ResultsA total of 134 patients (72.4 % male, mean age 57.3 ±14.9 years) were eligible for this substudy, of which 61 patients in the COVID-19 group and 73 patients in the pre-COVID-19 group. In both groups there was a similar percentage of primary prevention ICD implantations (COVID-19: 43%, pre-COVID: 44%; p=0.888). During COVID-19, RM was initiated more promptly following ICD implantation compared to pre-COVID-19 (respectively 63 days vs. 131 days; p=0.007). Second, in the COVID-19 group 60.7% patients were enrolled in RM within 30 days following implantation compared to 39.7% in the pre-COVID-19 group (p=0.016). In terms of arrhythmic burden, no differences in the occurrence of ICD therapy (p=0.759), NSVT (p=0.267) and SVT (p=0.454) were observed.ConclusionDuring the COVID-19 pandemic RM was initiated more promptly following ICD implantation compared to before the pandemic, however, no differences in arrhythmic burden between groups were observed.Uptake remote monitoring during COVID-19ICD therapy during 6 months follow-up

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.