Abstract

The objective of this study was to evaluate the performance of constructed wetland systems (SACs) for treatment of swine wastewater (ARS) under different organic loads (TCOA), and obtain kinetic parameters for sizing of the SACs. The SACs consisted of two tanks measuring 0.40 x 0.10 x 0.15 m, constructed of glass and filled with a 0.13 m layer of pea gravel; these were installed within a BOD incubator to maintain a 20°C temperature. The SACs were not cultivated and were submitted to average TCOA concentrations of 246 (SAC1) and 328 kg ha -1 day -1 of BOD (SAC2) for 51 days. With regard to the removal of organic matter, in the form of TSS, BOD and COD, no statistical difference was verified (p > 0.05) between the SACs, being that the average removal efficiencies for the referred variables in SAC1 and SAC2 were 68 and 76%, 66 and 73%, and 55 and 58%, respectively. The models proposed by Brasil et al. (2007) and Kadlec and Wallace (2008) presented good fit and adequately described the kinetics of organic matter removal (BOD and COD) from the evaluated systems, generally presenting R2 greater than 99%.

Highlights

  • The objective of this study was to evaluate the performance of constructed wetland systems (SACs) for treatment of swine wastewater (ARS) under different organic loads (TCOA), and obtain kinetic parameters for sizing of the sistemas alagados construídos (SACs)

  • Entre estas novas tecnologias surgem os sistemas alagados construídos ou constructed wetlands

  • Dois sistemas alagados de escoamento subsuperficial horizontal (SACs), em escala laboratorial, foram constituídos por caixas de vidro, nas dimensões de 0,15 m de altura x 0,10 m de largura x 0,40 m de comprimento com declividade de 0,01 mm (Figura 1)

Read more

Summary

Montagem do experimento

Dois sistemas alagados de escoamento subsuperficial horizontal (SACs), em escala laboratorial, foram constituídos por caixas de vidro, nas dimensões de 0,15 m de altura x 0,10 m de largura x 0,40 m de comprimento com declividade de 0,01 mm (Figura 1). Longitudinal de cada SACs foram implantados dois tubos de PVC de 0,0125 m de diâmetro, perfurados e espaçados de 0,133 m, para possibilitar a amostragem da ARS ao longo do sistema. Os SACs foram instalados dentro de uma estufa tipo BOD, para manutenção da temperatura de 20oC, e abastecidos com ARS utilizando-se frascos de Mariotte. Sistemas alagados de escoamento subsuperficial horizontal (SACs), em escala laboratorial, utilizados no tratamento da água residuária da suinocultura. Antes de ser colocada nos frascos de Mariotte para ser aplicada nos SACs, a ARS passava por uma peneira com abertura de 0,001 m para remoção de sólidos

Condução do experimento
Variáveis Q
Monitoramento dos SACs
Findings
Desempenho dos SACs quanto à remoção de matéria orgânica
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.