Abstract
Arthroscopically modified Eden-Hybinette procedures for glenohumeral stabilization have been used for a long time. With the advancement of arthroscopic techniques and the development of sophisticated instruments, a double Endobutton fixation system has been used clinically to secure bone graft to the glenoid rim placed through a specifically designed guide. The purpose of this report was to evaluate clinical outcomes and serial glenoid remodeling process following all-arthroscopic anatomical glenoid reconstruction using autologous iliac crest bone grafting technique through 1-tunnel fixation. Forty-six patients with recurrent anterior dislocations and significant glenoid defects greater than 20% underwent arthroscopic surgery with a modified Eden-Hybinette technique. Instead of firm fixation, autologous iliac bone graft was fixed to the glenoid by double Endobutton fixation system through 1-tunnel placed in the glenoid surface. Follow-up examinations were performed at 3, 6, 12, and 24months. The patients were followed up for a minimum of two years using the Rowe score, the Constant score, the Subjective Shoulder Value, and the Walch-Duplay score; patient satisfaction with the procedure outcome was also rated. Graft positions, healing, and absorption were evaluated postoperatively with computed tomography imaging. At a mean follow-up of 28months, all patients were satisfied and had a stable shoulder. The Constant score improved from 82.9 to 88.9 points (P < .001), the Rowe score, improved from 25.3 to 89.1 points (P<.001), the Subjective Shoulder Value improved from 31% to 87% (P<.001), and the Walch-Duplay score improved from 52.5 to 85.7 points (P < .001). One donor-site fracture occurred during the follow-up period. All grafts were well-positioned and achieved optimal bone healing with zero excessive absorption. The preoperative glenoid surface (72.6%±4.5%) increased significantly immediately after surgery to 116.5%±9.6% (P < .001). After a physiological remodeling process, the glenoid surface remained significantly increased at the last follow-up (99.2%±7.1%) (P < .001). The glenoid surface area appeared to decrease serially when compared between the first 6months and 12months postoperatively, while there was no significant interval change between 12 and 24months postoperatively. Patient outcomes were satisfactory following the all-arthroscopic modified Eden-Hybinette procedure using an autologous iliac crest grafting technique through one-tunnel fixation system with double Endobutton. Graft absorption mostly occurred on the edge and outside the ''best-fit'' circle of the glenoid. Glenoid remodeling occurred within the first year after all-arthroscopic glenoid reconstruction with an auto iliac bone graft.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.