Abstract

Background: Thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD) induces false lumen (FL) thrombosis, promotes favorable aortic remodeling, and makes an impact on abdominal aortic branch perfusion patterns. However, little is known about the long-term fate of aortic remodeling and abdominal aortic branch perfusion after TEVAR for TBAD and the effect of FL thrombosis status on these changes.Materials and methods: Between January 2014 and May 2021, 59 enrolled patients with acute TBAD were treated with TEVAR and had post-operative or follow-up images. Pre-operative, post-operative, and latest follow-up CT angiography (CTA) data were analyzed for the largest diameter of true lumen (TL), FL, and transaorta and for the FL thrombosis status on the stented thoracic aorta, unstented thoracic aorta, and abdominal aorta. Abdominal aorta perfusion patterns were characterized.Results: The mean follow-up period was 17.1 months. In the stented thoracic aorta, average TL diameters increased, average FL diameters decreased, and average transaortic diameters did not change; 82.6% of the patients had either a stable or shrinking transaortic size and 87% of the patients achieved total FL thrombosis. In the unstented thoracic aorta, average TL diameters increased, transaortic growth and no changes occurred in 39.1 and 45.7% of the patients, respectively, and complete FL thrombosis was present in 50% of the patients. In the abdominal aorta, average FL and transaortic diameters increased, aorta was expanded in 52.2% of the patients, and FL remained patent in 65.2% of the patients. Of the 354 branches, 37 branches (10.5%) exhibited changes in perfusion patterns, 22 branches (6.2%) demonstrated an increased TL perfusion, and 15 branches (4.2%) had an increased FL contribution. Compared with patent or partially thrombosed FL, complete FL thrombosis was accompanied by a bigger decrease in FL diameters, a larger increase in TL diameters, and a higher percentage of abdominal branch TL perfusion.Conclusions: In majority of the patients, TEVAR stabilized the size of the stented thoracic aorta, namely TL expansion and FL obliteration. However, abdominal aortic FL remained patent FL, and it was expanded with the resultant transaortic growth over a long follow-up period. Abdominal aortic branch perfusion patterns remained largely stable after TEVAR. The failure to achieve FL thrombosis negatively affects the remodeling of a contagious abdominal aortic dissection.

Highlights

  • Thoracic endovascular aortic repair (TEVAR) with stent graft coverage of a proximal entry tear was firstly reported for an aortic dissection in 1999 [1]

  • Complete false lumen (FL) thrombosis, mainly in the stent graftcovered thoracic aorta, may invoke positive remodeling, whereas a patent FL correlates with a higher risk of aortic dilation and death [6]

  • Three (5.1%) patients had no obvious clinical symptoms, TEVAR was selected after abnormalities were found at a physical examination

Read more

Summary

Introduction

Thoracic endovascular aortic repair (TEVAR) with stent graft coverage of a proximal entry tear was firstly reported for an aortic dissection in 1999 [1]. Thoracic endovascular aortic repair for TBAD reduces false lumen (FL) blood flow, induces FL thrombosis, and allows endograft-assisted true lumen (TL) expansion by the closure of the primary intimal tear with the placement of a covered stent graft into TL. Thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD) induces false lumen (FL) thrombosis, promotes favorable aortic remodeling, and makes an impact on abdominal aortic branch perfusion patterns. Little is known about the long-term fate of aortic remodeling and abdominal aortic branch perfusion after TEVAR for TBAD and the effect of FL thrombosis status on these changes

Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.