Background: When conservative management fails, patients with stress urinary incontinence (SUI) are considered for surgical treatment. Simpler, more economical and less invasive surgical techniques, such as the Remeex® system, have been developed. Objectives: To analyze the objective effectiveness of the Remeex® system in the treatment of male stress urinary incontinence. To study survival and complication rates of the Remeex® system in male SUI patients. Materials and methods: Prospective observational study between July 2015 and May 2020. Group A (n = 7; GA) patients with mild SUI. Group B (n = 22; GB) patients with moderate SUI. Group C (n = 18; GC) patients with severe SUI. Effectiveness was assessed by the number of patients achieving complete and partial dryness. Complete dryness was defined as patients using 0–1 safety pads per day; partial dryness as a >50% reduction in the number of pads used. Results were analyzed using descriptive statistics, Student’s t-test. Chi2, Fisher’s exact test, ANOVA, and multivariate analysis. Significance was set at p < 0.05. Results: Mean age 69.76 years, mean follow-up 33.52 months. Objective effectiveness was observed in 89.36% of patients with incontinence. The effectiveness was 85.71% in GA, 90.91% in GB and 88.89% in GC. There were no significant differences among groups (p = 1.0000). 34.04% of patients with an implant required at least one readjustment, while 66.00% did not require any. There were no significant differences among groups (p = 0.113) Chi2 = 4.352. 95.74% of implants remained in place by the end of follow-up. We observed complications in 17.02% of patients. Conclusions: Remeex® system is an effective and safe method for male stress urinary incontinence treatment, regardless of the severity of the incontinence, with high survival and low complication and removal rates. System readjustments are required in one-third of the cases.

Highlights

  • The International Continence Society defines urinary incontinence (UI) as the manifestation of any kind of involuntary loss of urine

  • 65.96% of patients had a history of open radical prostatectomy, 25.53% of laparoscopic radical prostatectomy and 8.51% had a transurethral resection of the prostate (TURP)

  • Patients with stress urinary incontinence (SUI) are considered for surgical treatment, which comprises a variety of procedures, with adjustable sling implants such as the Remeex® system to be considered as some of the simplest, most economical and less invasive alternatives to the artificial urinary sphincter procedure (AUS) [4]

Read more

Summary

Introduction

The International Continence Society defines urinary incontinence (UI) as the manifestation of any kind of involuntary loss of urine. Patients with stress urinary incontinence (SUI) are considered for surgical treatment. Objectives: To analyze the objective effectiveness of the Remeex® system in the treatment of male stress urinary incontinence. To study survival and complication rates of the Remeex® system in male SUI patients. Group A (n = 7; GA) patients with mild SUI. Group B (n = 22; GB) patients with moderate SUI. Group C (n = 18; GC) patients with severe SUI. Objective effectiveness was observed in 89.36% of patients with incontinence. There were no significant differences among groups (p = 0.113) Chi2 = 4.352. Conclusions: Remeex® system is an effective and safe method for male stress urinary incontinence treatment, regardless of the severity of the incontinence, with high survival and low complication and removal rates. System readjustments are required in one-third of the cases

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.