Abstract

AbstractSea water intrusion and remediation in the Upper Floridan Aquifer in South Carolina is simulated using the finite‐element model SUTRA developed by the U.S. Geological Survey. A sensitivity analysis of the effect of the hydrogeologic parameters on the sea water recharge and seepage velocities is performed. An increase in confining unit and/or in aquifer conductivity results in an increase of the sea water recharge. An increase in aquifer porosity results in a decrease of the sea water recharge. Among the three remedial techniques simulated—reduced aquifer withdrawals, an injection well, and a combined injection and capture well—the reduced aquifer withdrawals and injection well are the best methods for preventing sea water intrusion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.