Abstract

Based on tunable diode laser spectroscopy with direct absorption measurement, we developed a reliable measurement scheme which can precisely detect water vapor concentration independent of the scattering (attenuation) caused by the non-water dust particles inside the observed humidity chamber. The relative water vapor concentration was measured at 2 ν 1 + ν 3 water vapor transition band by 938 nm distributed feed-back diode laser at different temperatures using the tunable diode laser spectroscopy technique. These relative water vapor concentrations are converted into the absolute water vapor concentrations and we confirmed that the experimental results at different temperatures are consistently independent of the attenuation. Our measurement system gives the consistent water vapor concentrations without regard to either high or low scattering caused by the non-water dust particles inside the observed humidity chamber.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.