Abstract

Urodynamic studies which included cough leak point pressure (CLPP) and pressure flow studies were performed at two visits 2 weeks apart. Reproducibility between the two visits and also between the two diagnostic groups, urodynamic stress incontinence (USI) and urodynamic mixed incontinence (UMI) were analysed. Thirty-one women completed both visits, of those 14 had USI in both sets of urodynamic studies, 11 had UMI on both visits, six had USI on one visit and UMI in the other. The urodynamic variables of maximum cystometric capacity and CLPP have the most repeatability. Analysis in women with USI alone compared to USI with detrusor overactivity (DOA) showed that the repeatability for pressure flow parameters and CLPP was better in women without DOA, of which the CLPP was significantly different (p = 0.036). Urodynamic variables are inconsistent. This may reflect variations in urinary tract behaviour.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.