Abstract

Reliability testing was performed on 3dB couplers manufactured by the Gould Fiber Optics Operation. No significant change in coupler performance was observed during the tests. The maximum change in coupling ratio during repetitive temperature cycling from -40°C to +85°C averaged only 1.6%. Following 250 cycles between -40°C and 85°C, the coupling ratio and polarization sensitivity remained within 0.8% and 0.3%, respectively, of their initial values. The coupling ratio also remained constant to within 1% when measured periodically during a 1500 hour, damp heat test conducted at 65°C and 85% relative humidity. Couplers were also subjected to vibrations from 10-5000 Hz at 9g's and shocks up to 2500g's. During these tests the coupling ratio remained constant to within 1%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.