Abstract

Wrist arthroscopy is considered the gold standard for diagnosis of intra-articular wrist conditions including triangular fibrocartilage complex (TFCC) tears; however, the ability to reliably diagnose TFCC pathology during wrist arthroscopy is unclear. The purpose of this study was to assess the reliability of the diagnosis of TFCC tears on wrist arthroscopy videos. Five hand surgeons reviewed 43 cases on a secure web-based platform at two time points separated by 4-6 weeks. Each case included a deidentified clinical vignette and wrist radiographs with ulnar variance measurements and an arthroscopy video of ulnar wrist pathology, averaging 42 seconds. Surgeons were queried on the presence of TFCC tear and Palmer and Atzei classifications. Interobserver/intraobserver reliabilities were determined using kappa coefficients. The interobserver reliability regarding the presence/absence of TFCC tear was fair-good, with kappa coefficients of 0.596 in the first round of case review and 0.708 in the second round. The overall intraobserver reliability for the presence/absence of TFCC tear was also fair-good, with a kappa coefficient of 0.567. For cases with central TFCC tears, the interobserver reliability regarding the presence of TFCC tear was perfect, with a kappa coefficient of 1.0. When central tears were excluded, the kappa coefficients decreased to 0.322 and 0.368 in each round. The interobserver reliability for the Palmer and Atzei classifications was low, with kappa coefficients of 0.220 and 0.121 in the first round and 0.222 and 0.123 in the second round. Experienced wrist arthroscopy surgeons demonstrated fair-good interobserver reliability for the diagnosis of TFCC tear on wrist arthroscopy. However, when central TFCC tears were excluded, interobserver reliability was poor. These findings demonstrate a need for a focus on education for wrist arthroscopy anatomy. This investigation demonstrated poor agreement in surgeon identification and classification of TFCC tears, aside from central TFCC tears. The low reliability has a direct bearing on treatment considerations for TFCC tears.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.