Abstract
To compare the reliability of the Patient and Observer Scar Assessment Scale (POSAS) with the Vancouver Scar Scale (VSS) in evaluating thyroidectomy scars. At 6 months after the operation, 112 patients who underwent thyroid surgery via collar neck incision were evaluated by two blinded plastic surgeons and two senior residents using the VSS and the observer component of the POSAS. In addition, the observer-reported VAS score and patient-reported Likert score were evaluated. Internal consistency, interobserver reliability, and correlations between the patient- and observer-reported outcomes were examined. The observer component of POSAS scores demonstrated higher internal consistency and interobserver reliability than the VSS. However, the correlations between the observer-reported VAS score and the patient-reported Likert score (0.450) and between the total sum of patient and observer component scores (0.551) were low to moderate. The POSAS is more consistent over repeated measurements; accordingly, it may be considered a more objective and reliable scar assessment tool than the VSS. However, a clinician's perspective may not exactly match the patient's perception of the same scar.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.