Abstract

The maximal lactate accumulation rate (VLamax) has been linked to lactic anaerobic performance. Hence, accurate and reliable assessment is crucial in sport-specific performance testing. Thus, between-day reliability data of rowing-specific VLamax assessment was examined. Seventeen trained rowers (eight females and nine males; 19.5±5.2 yrs; 1.76±0.08 m; 70.2±8.9 kg; V̇O2max: 54±13 ml/min/kg) performed 20-s sprint tests on two separate days (one week apart) on a rowing ergometer. VLamax, peak lactate concentration, time to peak lactate, and mean rowing power were measured. Good to excellent intraclass correlation coefficients (ICCs), low standard error of measurement (SEM), and acceptable levels of agreement (LoAs; 90% confidence interval) for VLamax (ICC=0.85; SEM=0.02 mmol/L/s; LoA±0.09 mmol/L/s), peak lactate (ICC=0.88; SEM=0.3 mmol/L; LoA±1.4 mmol/l), time to peak lactate (ICC=0.92; SEM=0.1 min; LoA±0.5 min), and mean rowing power (ICC=0.98; SEM=3 W; LoA±39 W) were observed. In addition, VLamax was highly correlated (r=0.96; p≤0.001) to rowing power. Thus, VLamax and sprint performance parameters can be measured highly reliably using this sport-specific sprint test in rowing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.