Abstract

An increased inter-rectus distance (IRD) is a common condition in late pregnancy and in the postnatal period. The condition is difficult to assess. Palpation is the most commonly used method to assess IRD. To date there is scant knowledge of intra and inter-tester reliability of palpation to measure IRD and how palpation compares with ultrasound measurements.The aims of this study were: 1) evaluate intra and inter-rater reliability of abdominal palpation; 2) validate abdominal palpation of IRD measurements using ultrasound imaging as a reference.Two physiotherapists (PTs) conducted the palpation study in random order, blinded to each other's assessments. IRD was measured as finger widths between the two rectus abdominis (RA) muscles. Ultrasound images were recorded at the same locations as the palpation test. A blinded investigator measured the IRD offline.Palpation showed good intra-rater reliability between days expressed by a weighted Kappa (wK) higher than 0.7 for both physiotherapists, and moderate inter-rater reliability (wK = 0.534). Ultrasound was found to be more responsive for differences in IRD compared with values obtained by palpation.The intra-rater reliability was higher than the inter-rater reliability. Besides the difference in experience with palpation testing between the PTs, this result may be due to differences in finger width and/or the subjective interpretation of abdominal soft-tissues pressure. Ultrasound measures are highly sensitive to changes of IRD, which is not possible to replicate by palpation assessment using a finger width scale.Palpation has sufficient reliability to be used in clinical practice. However, ultrasound is a more accurate and valid method and is recommended in future research of IRD.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call