Abstract
A mathematical model is established for the reliability of modularly redundant systems with unequal failure rates for the operating and standby units. The failure modes include failures of the active and standby units, three types of switch failures, and failures on system recovery. System reliability is considered for cases of both similar and dissimilar units, and for various restrictions on the failure parameters. It is shown that the most important failure parameters are those related to catastrophic failures, and that putting more reliable units as basic units, which operate initially, is important when switches and recovery are imperfect.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.