Abstract

ObjectiveAlthough metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples.MethodsMetabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models.ResultsIn fasting samples, a median ICC of 0.70 was observed. ICC values were <0.50 for 48% of amino acids, 27% of acylcarnitines, 18% of lysophosphatidylcholines and 4% of phosphatidylcholines. In non-fasting samples, the median ICC was 0.54. ICC values were <0.50 for 71% of acylcarnitines, 48% of amino acids, 44% of biogenic amines, 36% of sphingomyelins, 34% of phosphatidylcholines and 33% of lysophosphatidylcholines. Overall, reproducibility was lower in non-fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins.ConclusionA single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting.

Highlights

  • Advancement of analytical technologies has made high-throughput metabolic profiling of biological specimens possible [1]

  • A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing intraclass correlation coefficients (ICCs) >0.50 in fasting and non-fasting samples, respectively

  • ICCs were higher in fasting samples that are preferable to non-fasting

Read more

Summary

Objective

Metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples

Methods
Results
Introduction
Materials and Methods
Discussion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.