Abstract

BackgroundThe management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture.MethodsFive observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated.ResultsMeasurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt.ConclusionsBased on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle measurements may be useful, but intra-articular gap and step appear unreliable.Electronic supplementary materialThe online version of this article (doi:10.1186/s12880-016-0147-7) contains supplementary material, which is available to authorized users.

Highlights

  • The management of distal radial fractures is guided by the interpretation of radiographic findings

  • Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step

  • Interobserver reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step (Table 2)

Read more

Summary

Introduction

The management of distal radial fractures is guided by the interpretation of radiographic findings. Comprising 2.5 % of all Emergency Department (ED) presentations, fracture of the distal radius is the most common skeletal fracture type [1]. It occurs in approximately 10 % of Caucasian women over 65 years [2]. Radiographs of the distal radius are used for diagnosis, to guide treatment choices, assess fracture reduction and Watson et al BMC Medical Imaging (2016) 16:44 important. This investigation explored the reliability of these eight parameters in preparation for a study of their utility in guiding treatment decisions

Methods
Results
Discussion
Conclusion