Abstract
Children with cerebral palsy are at risk for progressive hip displacement. Since surveillance for hip displacement uses specific radiographic measurements to guide decision making, it is important to establish the reliability of these measurements, which include Reimer's migration percentage (MP), acetabular index or acetabular angle (AI or AA), and pelvic obliquity (PO). The purpose of this study was to determine the intraobserver and interobserver reliability of these radiographic measures among an international group of pediatric orthopaedic surgeons participating in the prospective international multicenter Cerebral Palsy Hip Outcomes Project (CHOP) currently underway to evaluate the outcomes of hip interventions in cerebral palsy. Two compact discs (CDs) containing the same 25 anteroposterior pelvis radiographs in Digital Imaging and Communications in Medicine (DICOM) format were provided to participating surgeons at least 2 weeks apart. To reduce the likelihood of recall or any effects of learning or fatigue, the order of the radiographs varied on the 2 CD versions, and participating surgeons received the 2 CDs in random order. The intraclass correlation coefficients (ICCs) were calculated to assess interobserver and intraobserver reliability. Mean absolute differences of hip measurements obtained at 2 time points were also calculated. The MP had the highest reliability followed by PO, AI, and AA with a mean intrarater ICC (SD; range) of 0.95 (0.04; 0.84 to 0.98); 0.92 (0.03; 0.85 to 0.97); 0.84 (0.05; 0.75 to 0.92); and 0.82 (0.14; 0.51 to 0.98); respectively. The mean interrater ICC (SD; range) for MP, PO, AI, and AA were 0.94 (0.05; 0.78 to 0.99); 0.90 (0.04; 0.76 to 0.99); 0.79 (0.08; 0.52 to 0.93); and 0.69 (0.23; 0.42 to 0.98) for MP, PO, AI, and AA, respectively. The mean (SD; 95% confidence interval) for the absolute difference between the 2 measurements for the raters was 4.9% (2.9%; 3.4%-6.4%); 3. 8 degrees (1.2 degrees; 3.1-4.5 degrees); 2.6 degrees (1.5 degrees; 1.7-3.5 degrees); and 1.3 degrees (0.3 degrees; 1.29-1.31 degrees) for MP, AI, AA, and PO, respectively. MP is a reproducible measure with excellent intrarater and interrater reliability. However, differences in MP of <7% should be treated with caution as these might be a consequence of measurement error. Although we found a high level of intrarater and interrater reliability of the AI, AA, and PO, these measurements are more variable and not ideal for use as discrete outcome measures. Instead, these parameters might be useful for prognostication and decision making when consistent trends are observed longitudinally over time which might be better indications of true change.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.