Abstract

This study aims to assess the reliability of smart converters for applications using 24V batteries. It compares degradation effects and lifetime durations for similar dissipated energies when these smart power switches are subjected to normal and extreme protection test conditions. Three experimental ageing tests have been performed: (i) ageing tests under normal protection mode, (ii) ageing tests under repetitive inductive avalanche switching and (iii) ageing tests under repetitive short-circuit. Evolution of several electrical parameters such as on-state resistance; threshold voltage and saturation current have been monitored. Tested devices under normal condition and under repetitive inductive avalanche have failed after about the same number of cycles with the same dissipated energy. However, several results show a significant decrease of the lifetime under repetitive short-circuit tests for a similar dissipated energy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.