A comparison between single short-term radon measurements and annual radon measurements in basements shows that significant uncertainties should be associated with the short-term measurements. Activated charcoal radon monitors which measure radon over a 3 to 7 day interval yield measurements that should carry a ± 90% uncertainty in terms of estimating annual radon concentration. Alpha-track radon monitors which measure radon over a 3 month interval should carry a ± 30% uncertainty. Decisions about home purchases, home remediation and the development of risk characterizations may often be incorrect if currently popular but unrealistically low estimates of uncertainty are applied to short-term radon measurements. Optimal results are obtained from year-long alpha-track measurements.