Hip joint proprioception is vital in maintaining posture and stability in elderly individuals. Examining hip joint position sense (JPS) using reliable tools is important in contemporary clinical practice. The objective of this study is to evaluate the intra-rater and inter-rater reliability of hip JPS tests using a clinically applicable measurement tool in elderly individuals with unilateral hip osteoarthritis (OA). Sixty-two individuals (mean age = 67.5 years) diagnosed with unilateral hip OA participated in this study. The JPS tests were evaluated using a digital inclinometer in hip flexion and abduction directions. The absolute difference between target and reproduced angle (repositioning error) in degrees was taken to measure JPS accuracy. The intraclass correlation coefficient (ICC (2.k), was used to assess the reliability. The Intra rater-reliability for hip JPS tests showed very good agreement in the lying position (hip flexion-ICC = 0.88–0.92; standard error of measurement (SEM) = 0.06–0.07, hip abduction-ICC = 0.89–0.91; SEM = 0.06–0.07) and good agreement in the standing position (hip flexion-ICC = 0.69–0.72; SEM = 0.07, hip abduction-ICC = 0.66–0.69; SEM = 0.06–0.08). Likewise, inter-rater reliability for hip JPS tests demonstrated very good agreement in the lying position (hip flexion-ICC = 0.87–0.89; SEM = 0.06–0.07, hip abduction-ICC = 0.87–0.91; SEM = 0.07) and good agreement in the standing position (hip flexion-ICC = 0.64–0.66; SEM = 0.08, hip abduction-ICC = 0.60–0.72; SEM = 0.06–0.09). The results support the use of hip JPS tests in clinical practice and should be incorporated in assessing and managing elderly participants with hip OA.
Highlights
Hip joint proprioception is vital in maintaining posture and stability in elderly individuals
This study aims to assess the intra-rater and inter-rater reliability of hip joint joint position sense (JPS) tests using a digital inclinometer in elderly participants with unilateral hip osteoarthritis
Intra-rater reliability for hip JPS tests in the standing position was good in flexion (ICC: 0.69–0.72) and abduction (ICC: 0.66–0.69) directions
Summary
Hip joint proprioception is vital in maintaining posture and stability in elderly individuals. Examining hip joint position sense (JPS) using reliable tools is important in contemporary clinical practice. The objective of this study is to evaluate the intra-rater and inter-rater reliability of hip JPS tests using a clinically applicable measurement tool in elderly individuals with unilateral hip osteoarthritis (OA). Different methods of testing hip JPS have been considered in current clinical practice, but the therapists must have access to a reliable tool that can accurately measure JPS19. Given the lack of data on the reliability of inclinometer measurements of hip JPS, additional research is vital to equip clinicians and researchers with the information necessary to make clinical judgments regarding the measurement’s accuracy. This study aims to assess the intra-rater and inter-rater reliability of hip joint JPS tests using a digital inclinometer in elderly participants with unilateral hip osteoarthritis
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.