Abstract
This paper deals with a system in which one unit is operating online and is backed my m spares as warm standbys. There are r repair facilities. The on-line unit has an arbitrary lifetime distribution, while the spares have exponential failure time distributions. The repair time distribution is also exponential. This problem, viewed as a queuing problem, cannot be solved; but by locating a set of renewal points, we write the equations governing the states of the system and calculate the reliability and availability. Explicit results are obtained in the case of five redundant units and three repair facilities.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.