Abstract

Background: The purpose of this study was to investigate about the reliability of measuring antero-posterior laxity within-subjects for in-vivo studies using a navigation system. Methods: The analysis was performed by enroling 60 patients undergoing anterior cruciate ligament ACL reconstruction, and assessing AP laxity during the Lachman and drawer tests. Results: For the navigation system standard deviation for intra-trial measures was 0.7 mm, thus the intra-trial repeatability coefficient was 2.2 mm; standard deviation for intra-trial measure was 1.2 mm, while the reference inter-trial repeatability coefficient between expert surgeons was 3.4 mm. Conclusions: In conclusion, this study suggests that KIN-Nav may represent a new method to measure and document AP laxity intra-operatively with improved accuracy and test the effect of surgical treatment in-vivo with higher sensitivity than in the past and this study quantify its reliability for within-subjects studies performed by a single expert surgeon.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.