Abstract
Background and Purpose: 3D ultrasonic measurement of carotid atherosclerotic lesions has emerged as an important tool for research and patient management. We sought to evaluate the accuracy and the reliability of a new easy-to-use magnetically tracked freehand 3D ultrasonic device with quick reconstruction time, allowing for anatomical orientation “at a glance” for calibration and distance measurements, with unique usability as a combined tool for image acquisition, registration and measurement within 3-D ultrasonic (US) volumes, which is furthermore connectable to every conventional US-machine. To enable a complete evaluation of the whole system, three different key points had to be addressed: the reproducibility of the calibration procedure, the absolute accuracy of the whole system and a direct comparison to CT and MRI imaging modalities. Materials and Methods: For validating our calibration method, a set of 6 calibrations was performed; each consisting of 6 records of a pyramid phantom taken from different positions and angles. To evaluate the accuracy of the whole 3D-ultrasound system, the point reconstruction accuracy and the distance accuracy were determined in a point phantom made out of a single metal wire vertically attached to the bottom of a plastic tub filled with water. For distance measurements, a precisely manufactured plastic tube phantom was scanned and the length between fixed landmarks on the tube was measured. In a final step, 3D US records acquired with Curefab CS were compared to CT and MRI scans; for this purpose all ultrasonic data was manually registered to the CT/MRI data. Results: Concerning calibration precision the tested Curefab CS system performs state of the art compared to reviews of recent freehand 3D-Ultrasound calibration methods. The point reconstruction measure for evaluation of system accuracy retrieved a mean point accuracy of 1.52 mm in contrast to values ranging from 1.67 to 3.63 mm. Mean total error of distance measurements was 0.9% with standard deviation 0.56% in our study, compared with values reaching from about 1% up to 2.3% in other studies on this subject. All quantitative measurement results are listed in a summarized form in Table 1. Besides quantitative evaluation, 3D-ultrasound records acquired with the Curefab CS system were also compared to CT and MRI scans of patients (see Figure 3 and Figure 4). The alignment of both image modalities showed promising results for future development of diagnostic tools using all image data. Discussion and Conclusion: Our study demonstrates that 3D measurements with Curefab CS are feasible with satisfactory reliability and accuracy. From the results gathered in our study we conclude that 3D-imaging with Curefab CS might start off the possibility of accurate visualization, volume measurement, carotid plaque characterization and identification of vulnerable plaques in the very near future.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.