Abstract
The current standard to evaluate the presence of somatosensory dysfunctions is quantitative sensory testing, but its clinical utility remains limited. Low-cost and time-efficient clinical sensory testing (CST) batteries have thus been developed. Recent studies show moderate to substantial reliability in populations with neuropathic pain. This study evaluates the inter- and intra-tester reliability of people with spine-related leg and arm pain, representing mixed pain mechanisms. Fifty-three patients with spine-related leg (n = 41) and arm pain (n = 12) attended three CST sessions. The CST battery consisted of eleven tests, determining loss and gain of sensory nerve function. CST was performed by the same investigator twice and by an additional investigator to determine inter- and intra-tester reliability. Fleiss' (inter-tester) and Cohen's (intra-tester) kappa were calculated for dichotomized and intraclass correlation coefficients (ICC) for continuous outcomes. Fleiss' kappa varied among modalities from fair to substantial (κ = 0.23-0.66). Cold, warm, and vibration detection thresholds and cold and pressure pain thresholds reached kappa >0.4 (moderate to substantial reliability). Cohen's kappa ranged from moderate to substantial (κ = 0.45-0.66). The reliability of the windup ratio was poor (ICC <0.18). CST modalities with moderate to substantial inter-tester reliability could be of benefit as a screening tool. The moderate to substantial intra-tester reliability for all sensory modalities (except windup ratio) supports their potential use in clinical practice and research to monitor somatosensory changes over time in patients with spine-related limb pain of mixed pain mechanisms. We already know that most modalities of clinical sensory test (CST) batteries achieve moderate to substantial inter- and intra-tester reliability in populations with neuropathic pain. This study evaluates the reliability of a CST battery in populations with mixed pain mechanisms. We found inter-tester reliability varied from poor to substantial for sensory modalities, questioning the value of some CST modalities. The CST battery showed moderate to substantial intra-tester reliability, suggesting its usefulness to monitor sensory changes over time in this cohort.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.