Abstract
The paper examines the reliability of masonry walls designed for compression in accordance with AS3700. The results of a large number of tests on full-scale masonry walls in compression have been used to obtain probabilistic models of behaviour. Structural reliability was then estimated for vertical loading of unreinforced masonry walls loaded concentrically, considering variations of unit compressive strength, mortar type, tributary area and live-to-dead load ratios. A reliability-based calibration of the Australian masonry design code AS3700 was then conducted using a target reliability index specified in AS5104. Recommendations are made for changes to ϕ used for compression design in AS3700 that, if adopted, would lead to an increase of 66% in the design compressive strength of walls.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.