Abstract

The aim of this study was to clarify the method of the Duncan-Ely test and to estimate its interobserver reliability and validity by comparing it with three-dimensional gait analysis (3DGA). This study included 36 consecutive ambulatory patients with cerebral palsy (CP) who underwent preoperative 3DGA. The Duncan-Ely test was performed during three different velocities (slow, gravity, and fast). The interobserver reliability was assessed by three examiners. The results of the test were compared with kinematic variables derived from the gait analysis to assess the sensitivity and specificity of the test. The cut-off value was determined at the point of trade-off between the highest sensitivity and specificity. The intraclass correlation coefficient measuring interobserver reliability of the Duncan-Ely test was greatest during fast velocity (0.819). The sensitivity and specificity of the test during gravity velocity for knee range of motion total were 63.0% and 100% respectively, with a cut-off value of 78.3°. The sensitivity and specificity of the test during fast velocity for knee range of motion total were 66.7% and 100% respectively, with a cut-off value of 65°. The Duncan-Ely test shows excellent reliability in fast knee-flexion velocity, and good sensitivity and specificity compared with 3DGA during physical examination as a preoperative assessment of rectus femoris spasticity in patients with CP.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.