Abstract

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Pit and fissure caries presents diagnostic challenges due to its anatomical complexity and fluoride exposure. ICDAS II is a coding system for caries detection using clinical visual inspection. It identifies carious lesions by the change in colour, texture and surface integrity. Magnification might facilitate better detection of the lesions by enhancing the visual acuity. Thus, the objective of this study is to compare the reliability and validity of ICDAS II in detection of occlusal caries, with and without magnification, by using histological standard</span>.</p><p class="abstract"><strong>Methods:</strong> <span lang="EN-IN">This single blinded, randomized study included 334 unrestored extracted human premolars and molars. Two examiners independently scored pit and fissure caries status using ICDAS II criteria without magnification and later under 6 x magnification using surgical microscope. The samples were sectioned and lesions were scored using the ERK histological criteria, under Stereo microscope. The scores of the examiners were correlated with the histological scoring. Kappa statistics and Spearman correlation coefficients were performed. Optimal sensitivity, specificity of visual and enhanced visual examination was calculated by Receiver Operating Characteristic Curve (ROC). Likelihood ratios (LR) were also calculated. </span></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">The kappa values for Inter examiner reproducibility of visual and enhanced visual examination under microscope were 0.638-0.694 and for histological examination it was 0.979. Intra examiner reproducibility for visual and enhanced visual examination was 0.665 – 0.594. There was a strong relationship between visual, enhanced visual and histological examinations. Spearman’s correlation coefficient of ICDAS-II visual and enhanced visual examination for each examiner, to ERK histological scores was 0.869-0.848. The sensitivity and LR+ for visual and enhanced visual examination was decreased as the ICDAS score was increased and specificity and LR- increased with increased ICDAS score</span>.</p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-IN">Reliability and validity of ICDAS scoring in detecting occlusal caries under magnification did not differ from clinical visual inspection</span><span lang="EN-IN">. </span></p>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.