Abstract

BackgroundNeck pain has a significant global impact, ranking as the fourth leading cause of disability. Recurrent neck pain often leads to impaired sensorimotor control, particularly in craniocervical flexion (CFF). The Craniocervical Flexion Test (CCFT) has been widely investigated to assess the performance of deep cervical flexor muscles. However, its use requires skilled assessors who need to subjectively detect compensations, progressive increases in range of motion (ROM) or excessive superficial flexor activation during the test. The aim of this study was to design and develop a novel Craniocervical Flexion Movement Control Test (CFMCT) based on inertial sensor technology and real-time computer feedback and to evaluate its safety and usability, as well as inter and intra-rater reliability in both healthy individuals and patients with neck pain.MethodsWe used inertial sensor technology associated with new software that provides real-time computer feedback to assess CCF movement control through two independent test protocols, the progressive consecutive stages protocol (including progressive incremental stages of ROM) and the random stages protocol (providing dynamic and less predictable movement patterns). We determined intra and inter-rater reliability and standard error of the measurement for both protocols. The participants rated their usability was analysed through the System Usability Scale (SUS) and possible secondary effects associated with the tests were registered.ResultsThe progressive consecutive stages protocol and the random stages protocol were safe and easy to use (SUS scores of 82.00 ± 11.55 in the pain group and 79.56 ± 13.36 in the asymptomatic group). The progressive consecutive stages protocol demonstrated good inter-rater reliability (intraclass correlation coefficient [ICC] ≥ 0.75) and moderate to good intra-rater reliability (ICC 0.62–0.80). However, the random stages protocol exhibited lower intra-rater reliability, especially in the neck pain group, where the reliability values were poor in some cases (ICC 0.48–0.72).ConclusionThe CFMCT (progressive consecutive stages protocol) is a promising instrument to evaluate CCF motor control in patients with chronic neck pain. It has potential for telehealth assessment and easy adherence for exercise prescription and seems to be a safe and usable tool for patients with pain and asymptomatic individuals. Its use as a test or for exercise needs to be further investigated to facilitate its transfer to clinical practice.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.