Abstract

Background: In acute ischemic stroke, diffusion-weighted imaging (DWI) volume is an independent predictive factor of poor outcome and an exclusion criterion for thrombolytic treatment. A simplified diameters method (ABC/2, orthogonal diameter [OD], and the maximum diameter [MD]) was proposed to replace the conventional measuring method and overcome the tedious and time-consuming defects, but its accuracy remains to be determined. Objective: The objective of this study is to clarify the reliability and reproducibility of the diameter-based estimations in the infarct volume in DWI (Vol-DWI) measured by automated software. Methods: Data of 316 patients with acute ischemic stroke who underwent MRI within 72 h at Jinling Hospital were retrospectively reviewed. Subgroup analysis by the location (cortex, white matter and deep gray nuclei, and combined) and volume (<70 and >70 mL) of cerebral infarction was evaluated. Relationship and consistency between the diameters methods and Vol-DWI were determined using Spearman rank correlation, Wilcoxon signed-rank test, and Bland-Altman plots. The OD and MD thresholds indicating infarct size >15, 70, and 100 mL were determined by generating receiver-operating characteristic (ROC) curves. Interobserver reliability was established using intraclass correlation coefficient and Bland-Altman plot. Results: There was a strong positive correlation between the diameters and the Vol-DWI (ABC/2: r = 0.992, OD: r = 0.984, MD: r = 0.970, p < 0.001). Infarct volumes measured using the ABC/2 formula were significantly lower than those measured with Vol-DWI (Wilcoxon signed-rank test, z = 6.476, p < 0.001). Bland-Altman plot showed that the agreement of the volume <70 mL group, and white matter and deep gray nuclei groups was better than that of the other subgroups. For infarct volumes >15, 70, and 100 mL, the cutoff value for the MD was identified at 5, 6.9, and 8.4 cm, and the OD was identified at 12.47, 26.4, and 36.4 cm<sup>2</sup>, respectively, with a sensitivity and specificity >90%. Conclusions: The MD method was the best for achieving a rapid and excellent interobserver reliability for estimating infarct volume. Both OD and MD methods can quickly screen patients suitable for recanalization treatment and predict poor prognosis through threshold evaluation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.