Abstract
In the future, it is expected that treatment of Dupuytren disease (DD) may shift toward control of early disease. Ultrasound might be an accurate method to measure the outcome of such treatment. The aim of this study was to assess the reliability of sonographic measurement of palmar nodules. Fifty patients with nodules characteristic for early disease were assessed with ultrasound by 2 observers. Four different aspects of DD nodules were measured in the transversal and sagittal planes, width, depth, circumference, and area. The intra- and interobserver reliabilities were calculated using the intraclass correlation coefficient (ICC). The standard error of measurement (SEM) and the smallest detectable change (SDC) were also calculated for each aspect. The intraobserver reliability was good (ICC, 0.724 [0.562-0.833] to 0.886 [0.808-0.934]), except for width in the sagittal direction (ICC, 0.671 [0.484-0.799]). The interobserver reliability was moderate (ICC, 0.385 [0.126-0.596] to 0.757 [0.538-0.869]). The intraobserver ICCs of area were highest (transverse, 0.847 [0.744-0.893]; sagittal, 0.886 [0.808-0.934]). The SEM and SDC of area were 6.1 and 16.9 mm2 in the transverse and 8.0 and 22.2 mm2 in the sagittal plane. The intraobserver reliability of sonographic assessment of DD nodules is good. The measurement of area is the most reliable and is, therefore, recommended for future studies. However, even single-observer measurements have a clear dispersion, and a change beyond 16.9 (61%) and 22.2 mm2 (79%) has to be observed in the transverse and sagittal planes, respectively, before it can be considered as regression or progression. Repeated ultrasonographic measurements in DD should ideally be done by a single observer, using area of the nodule in the sagittal plane. Change beyond 16.9 (transverse) and 22.2 (sagittal) mm2 can be considered as a real change in nodule size.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: The Journal of Hand Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.