Abstract

Abstract The aim of the study was to determinate the fracture mechanism of firefighters’ helmets caused by the impact load in simulated operational conditions. Moreover the aim of the study was to assess the reliability of the personal protective equipment. Tests were conducted with the use of the drop tower system. On each type of helmet 5 impact tests were performed. The active force corresponding to impact energy of 60 J and the passive force (force in the place of the neck spine) was registered. Based on the results, it can be statement that helmets’ structure influences their reliability and values of the active and passive forces. Additionally, the majority of tested helmets exceeded the acceptable threshold values of passive force.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.