Background and Study Aim. The aim of this study was to analyse reliability and validity of accelerometer-based Iphone® Level application for measuring lower extremity active flexion and extension joint range of motion. Material and Methods. Thirty physically healthy students enrolled in sport sciences (11 males, 19 females, 21.2±1.5 years, Body mass 64.4±10.0 kg, Height 1.68±0.8 m, Fat percentage 21.2±7.8 %, 22.5±2.6 kg/m2) participated in the measurements of hip, knee, and ankle joint range of motion twice through Universal goniometer and Iphone® Level applications. The same experienced measurer carried out blind study of plantarflexion, dorsiflexion and knee flexion/extension, hip flexion/extension joint range of motion three times for each measurement methods and the other researcher recorded the results. For simultaneous validity analysis Pearson coefficient of correlation was used to decide the level of adaptation between the two intraclass correlation coefficient and Cronbach’s alpha values. Bland-Altman graphics were utilized for level of agreement between these two different methods. Results. The results of Pearson coefficient of correlation analysis revealed a positive correlation between the measurement values of joint range of motion performed through Universal goniometer and Level App (r2 = 0.44-0.94, p <0.05). Bland-Altman graphics showed a good agreement among Cronbach Alpha values and intraclass correlation coefficient in the confidence range of %95, and universal goniometers and Level App application. Conclusions. The results of this study revealed that goniometric measurements using Iphone® Level App is a good reliable method for measuring lower extremity active range of motion compared to universal goniometer.
Highlights
Background and Study AimThe aim of this study was to analyse reliability and validity of accelerometer-based Iphone® Level application for measuring lower extremity active flexion and extension joint range of motion
The results of Pearson coefficient of correlation analysis revealed a positive correlation between the measurement values of joint range of motion performed through Universal goniometer and Level App (r2 = 0.44-0.94, p
Bland-Altman graphics showed a good agreement among Cronbach Alpha values and intraclass correlation coefficient in the confidence range of %95, and universal goniometers and Level App application
Summary
The aim of this study was to analyse reliability and validity of accelerometer-based Iphone® Level application for measuring lower extremity active flexion and extension joint range of motion. In the light of information in the literature, the main aim of this study is to analyse interclass reliability and concurrent validity of level application on Iphone® smart phones with universal goniometer for active joint range of motion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.