Abstract

ObjectiveTo assess the inter-observer variability and accuracy of Mid Upper Arm Circumference (MUAC) and weight-for-length Z score (WFLz) among infants aged <6 months performed by community health workers (CHWs) in Kilifi District, Kenya.MethodsA cross-sectional repeatability study estimated inter-observer variation and accuracy of measurements initially undertaken by an expert anthropometrist, nurses and public health technicians. Then, after training, 18 CHWs (three at each of six sites) repeatedly measured MUAC, weight and length of infants aged <6 months. Intra-class correlations (ICCs) and the Pitman’s statistic were calculated.ResultsAmong CHWs, ICCs pooled across the six sites (924 infants) were 0.96 (95% CI 0.95–0.96) for MUAC and 0.71 (95% CI 0.68–0.74) for WFLz. MUAC measures by CHWs differed little from their trainers: the mean difference in MUAC was 0.65 mm (95% CI 0.023–1.07), with no significant difference in variance (P = 0.075).ConclusionMid Upper Arm Circumference is more reliably measured by CHWs than WFLz among infants aged <6 months. Further work is needed to define cut-off values based on MUAC’s ability to predict mortality among younger infants.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.