Abstract

The aim of the study was to assess the accuracy and reliability of skull angles measured on 3D models created by laser scanning. Five skulls were measured through both conventional and digital measuring methods. The 3D models were created using a hand-held laser scanner Creaform VIUscan™. Seven angular characteristics were measured three times by two observers. The intra- and interobserver reliability were assessed using intraclass correlation coefficient. The differences between the digital and direct measurements were assessed using the measurement and relative errors. The intraclass correlation coefficients for digitally taken angles indicated almost perfect intra- and interobserver reliability, except for the alveolar profile angle showing moderate interobserver agreement. The overall measurement error based on the differences between digitally and directly measured angles was 0.61° and the relative error was 0.68%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.