Abstract

Abstract To verify the reliability of the Earth Pressure Balance (EPB shield machine) hinged system, firstly, this paper analyses the reliability of the remanufactured EPB shield machine hinged system and then aims at the problem of the high failure rate of the hinged system in EPB shield machine. A fault tree model was established, and the qualitative and quantitative analysis of the fault tree was carried out. Finally, it is determined that the main cause of the oil cylinder malfunction in the hinged system is the insufficient pressure caused by the malfunction of the solenoid valve’s directional switching.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.