Abstract

The AASHTO LRFD Bridge Design Specifications state that the spacing between the shear connectors for steel girders should not exceed 610 mm (24 in.). This decision was made based on research conducted more than three decades ago. The goal of this research is to investigate the possibility of extending this limit to 1,220 mm (48 in.) for stud clusters used with full-depth precast concrete deck panels installed on steel girders. This paper presents the history of the 610 mm (24 in.) limit, various formulas developed to calculate fatigue and design capacity for stud clusters and concerns about extending the current LRFD limit. This paper also presents information on the first phase of the experimental investigation, which is conducted on push-off specimens to validate extending the limit to 1,220 mm (48 in.).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.